CHAPTER 2: THE ENGINEERS MENU
In order to program system configurations from the keypad, you must be in the Engineer
Menu. The panel will enter the Engineering Menu after entering a valid engineer code when the
panel is in an unset state. Whilst in Engineer Mode all tamper alarms (including case tamper),
will be disabled.
2.1 Entering The Engineers Menu
NOTE: You will not be able to access Engineers Mode if Areas or Set levels are set.
The system must be fully unset
in order to gain access to the Engineer Menu. Access
maybe also denied if the user has disabled the “Allow Engineer Menu” in the Master
Manager Mode ‘Authorisation Required’ will be shown.
Enter Engineer Code (default 1111).
Any active faults will be shown. Press the
key.
SET / UNSET SYSTEM?” will be
displayed.
Press the key.
FORCE ARM ON 1
st
INPUT [01]” will be
displayed.
Press the key.
ENTER CODE” will be displayed and a
pulsed tone will be heard.
Enter Engineer Code (default 1111).
INHIBIT FIRE / HU?” will be displayed
Once you are in the Engineer Menu, a high pitch tone will be generated regularly to remind you
that you are still in the Engineer Menu.
2.2 Exiting The Engineer Menu
On completion of programming, the system can be returned back to normal mode by:
METHOD ONE
Use the scroll keys: and to scroll
to “EXIT ENGINEERS MODE
Press the key
You will be returned to day mode
METHOD TWO
When the display shows any main menu
item (i.e. an item shown in capitals) press
the key, you will be returned to day
mode.
Please see page: 62, for all fault codes that may appear when exiting Engineers.